Grafik: Logo Franzen Feuerschutztüren
Franzen Feuerschutztüren GmbH
Gerhard-Welter-Str. 7
D-41812 Erkelenz

phone +49 (0) 2431-80070

Franzen smoke control doors

Double-leaf smoke control door RSN-2 CE according to European standard

Franzen smoke control door RSN-2 CE "System Schröders"

Double-leaf smoke control door / flap S200-C5 according to EN 16034

Smoke control

Sa / S200 tested according to EN 1634-3

  • as gate according to DIN EN 13241
  • as external door according to DIN EN 14351-1
Thermal transmittance

UD-value ≥ 1.2 W/(m²K) according to EN ISO 10077-1

Combinable with additional performance characteristics:

Burglar resistance
(optional)

RC4 - classification report no. 22-7/15.119, PIV-Velbert
RC3 - classification report no. 22-6/15.117, PIV-Velbert
RC2 - classification report no. 212 24303, ift Rosenheim
RC1 - classification report no. 212 24302, ift Rosenheim

according to DIN EN 1627 ff

Acoustic performance
(optional)

up to RW (C;Ctr) = 48 (-1;-5) dB

according to EN ISO 10140-1 / EN ISO 10140-2 / EN ISO 717

proof of airborne sound insulation for security doors
(measurement reports, test reports, expert opinions)

Air tightness
(optional)

up to class 3 according to EN 12207 (up to 600 Pa)

expert opinion no. 40-40/12.120, PIV Velbert
Resistance to positive and negative pressure
(optional)

up to 3.800 Pa according to DIN EN 12211

expert opinion no. 40-52/16.120
Behavior between different climates
(optional)

class 2 (d + e) according to EN 12219 (deflection)

Ability to release
(optional)

according to DIN EN 16034
hold-open device according to DIN EN 14637

according to DIN EN 14351-1
proven for doors in escape and rescue routes

Flush with surface
(optional)

flush-mounted design FLAT

Explosion protection
(optional)
Logo ATEX For installation in potentially explosive areas, please see confirmation letter Explosion protection ATEX for Franzen hinged doors (in German language) System Schröders (PDF)

Performance characteristics combinable with further Franzen door types:

Fire resistance
(optional)

tested EI290 (fire door EI290 Franzen TSN-12)
tested EI260 (fire door EI260 Franzen TSN-4)
tested EI230 (fire door EI230 Franzen TSN-2)

according to EN 1634-1

Technical data
Dimensions
(rough building dimension)
width from 1,250 mm up to 4,050 mm
height from 1,900 mm up to 4,050 mm
Door leaf

leaf thickness 68 mm to 69 mm - smooth double-walled
plate thickness 1.0 mm to 1.5 mm

  • thin rebate design
    • optional thick rebate design
    • insulating insert
      • optional insulation inlet full-face glued and pressed with cover plate
        thus particularly plane and smooth door leaf
Frame
  • frame-system "ZNG" (see installation variants)
  • corner frame
  • optional enclosing frame
  • optional block frame
  • optional frame 4-sided
Floor seal

lowerable floor seal

  • optional sliding seal (patented)
Glass inset
(optional)

glass dimensions and -form variable

minimum frieze width: 130 mm

  • optional with intermediate glass inset bars
  • optional with port-hole (ø approx. 450 mm clear view)

glass inset bars with concealed screw connection (for rectangular glass inset)

Hinges

per leaf 2/3-part KO door hinges
with patented easy-running bearings as easy running doors

  • optional door hinge with 3D adjustment
Fittings active leaf
  • optional any approved handle set according to EN 1906 resp. EN 179
  • optional panic bar handle or push bar according to EN 1125

for version RC: Protective fitting ES-1 up to ES-3

Locking active leaf

single locking according to EN 12209, depending on version multi-point locking
profile cylinder prepared (cylinder on-site)

fixed leaf

internal snap bolt (locking upwards)
depending on version, with locking upwards and downwards (rebate shoot bolt, shoot bolt lock)

securing pins at both leafs

  • optional panic locking according to EN 179 resp. EN 1125
Self-closing

both leafs with door closer according to DIN EN 1154 resp. EN 1155
with door closing sequence control according to EN1158

Installation
  • in masonry(thk ≥ 115 mm)
  • in concrete(thk ≥ 100 mm)
  • in aerated concrete(thk ≥ 150 mm)
  • in mounting walls min. F30(thk ≥ 100 mm)
  • in encased steel columns min. F30(thk ≥ 100 mm)
  • optional blunt installation in soffit
  • optional installation on the wall plate
  • approved for installation at great heights (installation not at floor level: height on one or both sides > 500 mm above ground level - e.g. as manhole door/flap) with lower fire and smoke seal - also thresholdless
Marking

CE-Zeichen marking for firedoors according to EN 16034

Optional
  • lock control
  • automated opening
  • motor locks ( also in 3-way locking)
  • powder coating in RAL colors
  • prison cell doors (special locking and food flap)
  • special solutions according to request and customer requirements

The information given refers to the usual configurations. Individual configurations may be required when combining different performance characteristics.

Our team will be happy to assist you with the individual planning of your requirements.

  • Feuerschutztür RSN-2
    Franzen RSN-2 CEdouble-leaf smoke control door"System Schröders"

RSN-2 CE Downloads