Grafik: Logo Franzen Feuerschutztüren
Franzen Feuerschutztüren GmbH
Gerhard-Welter-Str. 7
D-41812 Erkelenz

phone +49 (0) 2431-80070

Franzen steel doors and gates

Overview table

Franzen steel doors and gates

Hinged doors, hinged gates, hinged flaps Fire resistance Smoke control Burglar resistance
EN 1627 ff
Acoustic performance
EN 20140
EN ISO 10140
EN ISO 717-1
Airtightness
wind load
watertightness
Positive and negative pressure
EN 12211
Designation Number of
leaves
Dimensions*
width x height
(in mm)
FLAT Resistance Designation Resistance-
class
dB Class
TSN-1 EI230 fire door class EI2 acc. to EN 16034 CE marked 1
from 525  x  500
up to 2,300  x  4,600
EI230-Sa-C5 S200 RC4
RC3
RC2
RC1
up to
RW(C;Ctr)
= 53 (-1;-5) dB
airtight up to 4
wind up to C5
rain up to 8A
up to 5,000 Pa
TSN-2 EI230 fire door class EI2 acc. to EN 16034 CE marked 2
from 1,250  x  1,900
up to 4,600  x  4,600
EI230-Sa-C5 S200 RC4
RC3
RC2
RC1
up to
RW(C;Ctr)
= 48 (-1;-5) dB
airtight up to 3
wind up to C4
rain up to 3A
up to 3,800 Pa
TSN-3 EI260 fire door class EI2 acc. to EN 16034 CE marked 1
from 525  x  750
up to 1,750  x  3,500
EI260-Sa-C5 S200 RC4
RC3
RC2
RC1
up to
RW(C;Ctr)
= 53 (-1;-5) dB
airtight up to 4
wind up to C5
rain up to 8A
up to 5,000 Pa
TSN-4 EI260 fire door class EI2 acc. to EN 16034 CE marked 2
from 1,375  x  1,750
up to 3,500  x  3,500
EI260-Sa-C5 S200 RC4
RC3
RC2
RC1
up to
RW(C;Ctr)
= 48 (-1;-5) dB
airtight up to 3
wind up to C4
rain up to 3A
up to 3,800 Pa
TSN-11 EI290 fire door class EI2 acc. to EN 16034 CE marked 1
from 525  x  750
up to 1,500  x  2,950
EI290-Sa-C5 S200 RC4
RC3
RC2
RC1
up to
RW(C;Ctr)
= 53 (-1;-5) dB
airtight up to 4
wind up to C5
rain up to 8A
up to 5,000 Pa
TSN-12 EI290 fire door class EI2 acc. to EN 16034 CE marked 2
from 1,375  x  1,750
up to 3,250  x  3,250
EI290-Sa-C5 S200 RC4
RC3
RC2
RC1
up to
RW(C;Ctr)
= 48 (-1;-5) dB
airtight up to 3
wind up to C4
rain up to 3A
up to 3,800 Pa
EIS-11 EI2120 fire door class EI2 acc. to EN 16034 CE marked 1
from 500  x  750
up to 1,400  x  2,650
EI2120-Sa-C5 S200 RC4
RC3
RC2
RC1
- airtight up to 4
wind up to C5
rain up to 8A
up to 5,000 Pa
TSN-1 T-30 fire door DIBt approval 1
from 625 x 685
up to 1,500 x 3,000
with overhead / side panel
up to 3,430 x 3,165
T-30 RS RC4
RC3
RC2
RC1
up to
RW(C;Ctr)
= 53 (-1;-5) dB
airtight up to 4 up to
5,000 Pa
TSN-2 T-30 fire door DIBt approval 2
from 1,375 x 1,750
up to 3,000 x 3,000
with overhead / side panel
up to 3,700 x 3,200
T-30 RS RC4
RC3
RC2
RC1
up to
RW(C;Ctr)
= 48 (-1;-5) dB
Airtight up to 3 up to
3,800 Pa
TSN-11 T-90 fire door DIBt approval 1
from 625 x 660
up to 1,500 x 3,250
T-90 RS RC4
RC3
RC2
RC1
up to
RW(C;Ctr)
= 53 (-1;-5) dB
airtight up to 4 up to
5,000 Pa
TSN-12 T-90 fire door DIBt approval 2
from 1,375 x 1,750
up to 3,000 x 3,250
T-90 RS RC4
RC3
RC2
RC1
up to
RW(C;Ctr)
= 48 (-1;-5) dB
Airtight up to 3 up to
3,800 Pa
RSN-1 CE Smoke control door acc. to EN 16034 CE marked 1
from 525  x  500
up to 2,025  x  4,050
- S200-C5 RC4
RC3
RC2
RC1
up to
RW(C;Ctr)
= 53 (-1;-5) dB
airtight up to 4
wind up to C5
rain up to 8A
up to
5,000 Pa
RSN-2 CE Smoke control door acc. to EN 16034 CE marked 2
from 1,250  x  1,900
up to 4,050  x  4,050
- S200-C5 RC4
RC3
RC2
RC1
up to
RW(C;Ctr)
= 48 (-1;-5) dB
airtight up to 3
wind up to C4
rain up to 3A
up to
3,800 Pa
RSN-1 Smoke control door acc. to DIN 18095 1
from 500 x 500
up to 1,350 x 2,500
with overhead / side panel
up to 3,350 x 3,500
- RS RC4
RC3
RC2
RC1
- airtight up to 4
wind up to C5
rain up to 8A
up to
5,000 Pa
RSN-2Smoke control dooracc. to DIN 18095 2
from 1,375 x 1,750
up to 4,500 x 4,500
with overhead / side panel
up to 4,000 x 3,500
- RS RC4
RC3
RC2
RC1
- airtight up to 3
wind up to C4
rain up to 3A
up to
3,800 Pa
ESN-1Burglar resistance door 1
from 625 x 500
up to 1,500 x 3,000
- - RC4
RC3
RC2
RC1
up to
RW(C;Ctr)
= 53 (-1;-5) dB
airtight up to 4
wind up to C5
rain up to 8A
up to
5,000 Pa
ESN-2Burglar resistance door 2
from 1,050 x 1,750
up to 3,250 x 3,000
- - RC4
RC3
RC2
RC1
up to
RW(C;Ctr)
= 48 (-1;-5) dB
airtight up to 3
wind up to C4
rain up to 3A
up to
3,800 Pa
SN-1Acoustic performance door 1
from 600 x 600
up to 1,400 x 3,050
- - - up to
RW(C;Ctr)
= 53 (-1;-5) dB
airtight up to 4
wind up to C5
rain up to 8A
up to
5,000 Pa
SN-2Acoustic performance door 2
from 1,250 x 1,250
up to 3,450 x 3,450
- - - up to
RW(C;Ctr)
= 48 (-1;-5) dB
airtight up to 3
wind up to C4
rain up to 3A
up to
3,800 Pa
ASN-1External door 1 depending on performance characteristic - - - - airtight up to 4
wind up to C5
rain up to 8A
up to
5,000 Pa
ASN-2External door 2 depending on performance characteristic - - - - airtight up to 3
wind up to C4
rain up to 3A
up to
3,800 Pa
ISN-1Multi purpose door 1 no performance determined - - - - - -
ISN-2Multi purpose door 2 no performance determined - - - - - -
TR-1Transformer room door 1 no performance determined - - - - - -
TR-2Transformer room door 2 no performance determined - - - - - -
1) EN 12207
2) EN 12210
3) EN 12208
Fire doors and gates EI - classified Fire resistance Smoke control Burglar resistance
EN 1627 ff
Acoustic performance
EN 20140
EN ISO 10140
EN ISO 717-1
Airtightness
wind load
watertightness
Positive and negative pressure
EN 12211
EIS-1/60 Fire door class EI acc. to EN 16034 CE marked 1
from 625  x  1,750
up to 1,500  x  3,000
EI2 60
E 120
EW 60
(120 min. tested)
Sa / S200 - - airtight up to 4
wind up to C5
rain up to 8A
up to 5,000 Pa
EIS-2/60 Fire door class EI acc. to EN 16034 CE marked 2
from 1,275  x  1,875
up to 3,000  x  3,000
EI2 60
E 120
EW 60
(120 min. tested)
Sa / S200 - - airtight up to 3
wind up to C4
rain up to 3A
up to 3,800 Pa
Fire doors and gates E - classified Fire resistance Smoke control Burglar resistance
EN 1627 ff
Acoustic performance
EN 20140
EN ISO 10140
EN ISO 717-1
Airtightness
wind load
watertightness
Positive and negative pressure
EN 12211
ES-1/60 Fire door class E acc. to EN 16034 CE marked 1
max
1,580 x 3,100
E 60
EW 60
- - - - -
ES-1/120 Fire door class E acc. to EN 16034 CE marked 1
max
1,580 x 3,100
E 120
EW 60
- - - - -
ES-1/180 Fire door class E acc. to EN 16034 CE marked 1
max
1,580 x 3,100
E 180
EW 60
- - - - -
ES-1/240 Fire door class E acc. to EN 16034 CE marked 1
max
1,580 x 3,100
E 240
EW 60
- - - - -
ES-2/60 Fire door class E acc. to EN 16034 CE marked 2
max
3,100 x 3,100
E 60
EW 60
- - - - -
ES-2/120 Fire door class E acc. to EN 16034 CE marked 2
max
3,100 x 3,100
E 120
EW 60
- - - - -
ES-2/180 Fire door class E acc. to EN 16034 CE marked 2
max
3,100 x 3,100
E 180
EW 60
- - - - -
ES-2/240 Fire door class E acc. to EN 16034 CE marked 2
max
3,100 x 3,100
E 240
EW 60
- - - - -
1) EN 12207
2) EN 12210
3) EN 12208
Ceiling flaps for horizontal mounting Fire resistance Smoke control Burglar resistance
EN 1627 ff
Acoustic performance
EN 20140
EN ISO 10140
EN ISO 717-1
Airtightness
wind load
watertightness
Positive and negative pressure
EN 12211
Designation Number of
leaves
Dimensions*
width x height
(in mm)
FLAT Resistance Designation Resistance-
class
dB Class
THFT-90 fire ceiling flapDIBt approval 1
from 500  x  500
up to 1,100  x  1,350
- T-90 RS - up to
RW(C;Ctr)
= 42 (-1;-3) dB
airtight up to 4
wind up to C5
up to
5,000 Pa
DKN-1Multi purpose ceiling flap 1 depending on performance characteristic - - - RC4
RC3
up to
RW(C;Ctr)
= 45 (-1;-3) dB
airtight up to 4
wind up to C5
up to
5,000 Pa
DKN-2Multi purpose ceiling flap 2 depending on performance characteristic - - - RC4
RC3
up to
RW(C;Ctr)
= 45 (-0;-3) dB
airtight up to 4
wind up to C5
up to
3,800 Pa
Sliding doors and sliding gates
(available soon)
Fire resistance Smoke control Burglar resistance
EN 1627 ff
Acoustic performance
EN 20140
EN ISO 10140
EN ISO 717-1
Airtightness
wind load
watertightness
Positive and negative pressure
EN 12211
Designation Number of
leaves
Dimensions*
width x height
(in mm)
FLAT Resistance Designation Resistance-
class
dB Class
ST-1 EI230 Fire resistant
sliding gate class EI2 acc. to EN 16034 CE marked
1 (available soon) - EI230-Sa-C2 S200 - - - -
ST-2 EI230 Fire resistant
sliding gate class EI2 acc. to EN 16034 CE marked
2 (available soon) - EI230-Sa-C2 S200 - - - -
ST-11 EI290 Fire resistant
sliding gate class EI2 acc. to EN 16034 CE marked
1 (available soon) - EI290-Sa-C2 S200 - - - -
ST-12 EI290 Fire resistant
sliding gate class EI2 acc. to EN 16034 CE marked
2 (available soon) - EI290-Sa-C2 S200 - - - -
RST-1 Smoke control
sliding gate class S200 acc. to EN 16034 CE marked
1 (available soon) - - S200 C2 - - - -
RST-2 Smoke control
sliding gate class S200 acc. to EN 16034 CE marked
2 (available soon) - - S200 C2 - - - -
MST-1 Multi purpose
sliding gate acc. to EN 16034 CE marked
1 (available soon) - - - - - - -
MST-2 Multi purpose
sliding gate acc. to EN 16034 CE marked
2 (available soon) - - - - - - -
1) EN 12207
2) EN 12210
3) EN 12208