Grafik: Logo Franzen Feuerschutztüren
Franzen Feuerschutztüren GmbH
Gerhard-Welter-Str. 7
D-41812 Erkelenz

phone +49 (0) 2431-80070

Franzen smoke control doors

Single-leaf smoke control door RSN-1 according to DIN 18095

Franzen smoke control door RSN-1 "System Schröders"
Single-leaf smoke control door
Smoke control tested according to DIN 18095 RS-1
Allgemeines bauaufsichtliches Prüfzeugnis Nr.: P-BWU03-I 17.67.15,
MPA Stuttgart - Otto-Graf-Institut

Combinable with additional performance characteristics:

Burglar resistance
(optional)

RC4 - classification report no. 22-5/15.119, PIV-Velbert
RC3 - classification report no. 22-4/15.117, PIV-Velbert
RC2 - classification report no. 45-47/22, PIV-Velbert
RC1 - classification report no. 212 24294, ift Rosenheim

according to DIN EN 1627 ff

Thermal transmittance

UD-value ≥ 1.3 W/(m²K) according to EN ISO 10077-1

Air tightness
(optional)

up to class 4 according to EN 12207 (up to 600 Pa)

expert opinion no. 11-000082-PR01
Resistance to positive and negative pressure
(optional)

up to 5.000 Pa according to DIN EN 12211

expert opinion no. 16-003037-PR01
Flush with surface
(optional)

flush-mounted design FLAT

Explosion protection
(optional)
Logo ATEX For installation in potentially explosive areas, please see confirmation letter Explosion protection ATEX for Franzen hinged doors (in German language) System Schröders (PDF)

Performance characteristics combinable with further Franzen door types:

Fire resistance
(optional)

T90 (fire door T90 Franzen TSN-11)
T30 (fire door T30 Franzen TSN-1)

according to. allgemeine bauaufsichtliche Zulassung (German approval)

Technical data
Dimensions
(rough building dimension)
width from 500 mm up to 1,350 mm
height from 500 mm up to 2,500 mm
with overhead panel total height max. 3,500 mm
height overhead panel max. 1,000 mm
with side panel total width max. 3,350 mm
width per side panel max. 1,000 mm
Overhead panel
  • optional with overhead panel
Side panel
  • optional with side panel
Door leaf

leaf thickness 68 mm to 69 mm - smooth double-walled
plate thickness 1.0 mm to 1.5 mm

  • thin rebate design
    • optional thick rebate design
    • insulating insert
      • optional insulation inlet full-face glued and pressed with cover plate
        thus particularly plane and smooth door leaf
  • leaf weight ca. 20 kg/m
Frame
  • frame-system "ZNG" with flush clipped in Thelesol® fire protection strips
  • or
  • frame-system "ZG"
  • (see installation variants)
  • corner frame
  • optional enclosing frame
  • optional block frame

with elastic rubber seal
(seal type depending on performance characteristic)

Floor seal
  • optional lowerable floor seal or
  • sliding seal
Glass inset
(optional)

glass dimensions and -form variable

minimum frieze width: 90 mm

  • optional with intermediate glass inset bars
  • optional with port-hole (ø approx. 450 mm clear view)
  • optional in overhead / side panel

glass inset bars with concealed screw connection (for rectangular glass inset)

Hinges

2/3-part KO door hinges
with patented easy-running bearings as easy running doors

  • optional door hinge with 3D adjustment
Fittings
  • optional any approved handle set according to EN 1906 resp. EN 179
  • optional panic bar handle or push bar according to EN 1125
Locking

single locking according to EN 12209, depending on version multi-point locking
profile cylinder prepared (cylinder on-site)
securing pins

  • for version RC4: lock combination with triple locking
  • optional panic locking according to EN 179 resp. EN 1125
Self-closing

door closer according to DIN EN 1154

  • optional spring hinge for smaller doors / flaps
  • optional hold-open system according to DIN EN 14637
Installation
  • in masonry(thk ≥ 115 mm)
  • in concrete(thk ≥ 100 mm)
  • in aerated concrete(thk ≥ 150 mm)
  • in mounting walls min. F30 (thk ≥ 100 mm)
  • optional blunt installation in soffit
  • optional installation on the wall plate
Marking

mark of conformity - "Ü"
according to German conformity mark regulation

Optional
  • lock control
  • automated opening
  • motor locks ( also in 3-way locking)
  • powder coating in RAL colors
  • prison cell doors (special locking and food flap)
  • special solutions according to request and customer requirements

The information given refers to the usual configurations. Individual configurations may be required when combining different performance characteristics.

Our team will be happy to assist you with the individual planning of your requirements.

  • Feuerschutztür RSN-1
    Franzen RSN-1einflügelige Rauchschutztür"System Schröders"

RSN-1 Downloads