Franzen fire door class E

Single leaf fire door ES-1/60

Franzen fire door ES-1/60 "System Schröders"

Single-leaf fire door ES-1/60

CE-marking marked

Fire resistance

fire resistance period 60 minutes
tested according to EN 1634-1

Combinable with additional performance characteristics:

Resistance to positive and negative pressure
(optional)

up to 5.000 Pa according to DIN EN 12211

expert opinion no. 16-003037-PR01
Flush with surface
(optional)

flush-mounted design FLAT

Explosion protection
(optional)
Logo ATEX For installation in potentially explosive areas, please see confirmation letter Explosion protection ATEX for Franzen hinged doors (in German language) System Schröders (PDF)
Technical data
Dimensions
(rough building dimension)
width up to 1,580 mm
height up to 3,100 mm
area max. 3.9 m²
Door leaf

leaf thickness 68 mm to 69 mm - smooth double-walled
plate thickness 1.0 mm to 1.5 mm
leaf weight 25 - 30 kg/m²

  • thin rebate design
    • optional thick rebate design
    • insulating insert
      • optional insulation inlet full-face glued and pressed with cover plate
        thus particularly plane and smooth door leaf
Frame
  • frame-system "ZNG" with flush clipped in Thelesol® fire protection strips
  • (see installation variants)
  • corner frame
  • optional enclosing frame
  • optional block frame

with elastic rubber seal
(seal type depending on performance characteristic)

Glass inset
(optional)

glass dimensions and -form variable
(rectangular glass inset max. 800 mm x 800 mm)

minimum frieze width: 90 mm

  • optional with intermediate glass inset bars
  • optional with port-hole (ø approx. 450 mm clear view)

glass inset bars with concealed screw connection (for rectangular glass inset)

Hinges

2/3-part KO door hinges
with patented easy-running bearings as easy running doors

  • optional door hinge with 3D adjustment
Fittings
  • heavy metal handle set or other handle sets approved for fire doors
  • optional panic bar handle or push bar according
Locking

single locking according to EN 12209, depending on version multi-point locking
profile cylinder prepared (cylinder on-site)
securing pins

  • optional panic locking
Self-closing

door closer EN 1154 Dorma TS83 Code IMM

  • optional spring hinge for smaller doors / flaps
Installation
  • in masonry
  • in concrete
  • in aerated concrete
  • in mounting walls min. F60
  • in encased steel columns
  • optional blunt installation in soffit
  • approved for installation at great heights (installation not at floor level: height on one or both sides > 500 mm above ground level - e.g. as manhole door/flap) with lower fire and smoke seal - also thresholdless
Marking

CE-Zeichen marking for firedoors according to EN 16034

Optional
  • lock control
  • automated opening
  • motor locks ( also in 3-way locking)
  • powder coating in RAL colors
  • prison cell doors (special locking and food flap)
  • special solutions according to request and customer requirements

The information given refers to the usual configurations. Individual configurations may be required when combining different performance characteristics.

Our team will be happy to assist you with the individual planning of your requirements.

  • Feuerschutztür ES-1-60
    Franzen ES-1/60single-leaf fire door"System Schröders"

Downloads ES-1/60